Controlling the Multiple Product
RS-232C
13
Transmission / Receiving Protocol
22. Tile ID Set (Command : d i)
To assign the Tile ID for Tiling function.
Transmission
[d][i][][Set ID][][Data][x]
* The data range is from 00 to 10 tile mode. (in Hex).
Acknowledgement
[i][][Set ID][][OK/NG][Data][x]
▲
24. Inverter Adjust (Command : d r)
To adjust the Inverter.
Transmission
[d][r][][Set ID][][Data][x]
Data 0 : Inverter Off
1 : Inverter On
Acknowledgement
[r][][Set ID][][OK/NG][Data][x]
▲
23. Temperature check (Command : d n)
To read the inside temperature value.
Transmission
[d][n][][Set ID][][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][][Set ID][][OK/NG][Data][x]
Data are 1 byte long in Hex ASCII format.
▲