- Ambient Temperature Sensor Error
4
5
6
Error
Different
Proceed according to the error
shown on display
Yes
Normal
Same
Explain to customer.
Got to step 6.
42
1.
Remove the sensor cover.
2.
Cut the sensor and peel off the terminals.
3.
Make short circuit in the terminals from
the cabinet side.
4.
Measure the resistance for CON8.
1.
Reconnect CON8.
2.
Reset power in the refrigerator.
3.
Check that there’s no error on display.
Check the voltage between gray wires
(sensor wires) for CON8.
No
Checking
Result and SVC countermeasure
0
Short Change
sensor
OFF
Open Replace the product
Result SVC
Support
Result SVC
Support
0V
Out of
Control
Replace (PCB)
5V
Other value
between
0V & 5V
Normal
Result SVC
Support
1.
Check temperature and resistance
(see chart of section 7-2).
2.
Explain to customer about loose
and dirty connectors.
Содержание LTNS16121V /00
Страница 14: ...4 CIRCUIT DIAGRAM 14 ...
Страница 59: ...MFL49380062 December 2015 ...