°C
°F
-26.0
-14.8
104.60
4.56
-24.0
-11.2
94.30
4.52
-22.0
-7.6
85.14
4.47
-20.0
-4.0
76.96
4.43
-18.0
-0.4
69.66
4.37
-16.0
3.2
63.13
4.32
-14.0
6.8
57.29
4.26
-12.0
10.4
52.05
4.19
-10.0
14.0
47.34
4.13
-8.0
17.6
43.12
4.06
-6.0
21.2
39.31
3.99
-4.0
24.8
35.88
3.91
-2.0
28.4
32.79
3.83
0.0
32.0
30.00
3.75
2.0
35.6
27.47
3.67
4.0
39.2
25.19
3.58
6.0
42.8
23.12
3.49
8.0
46.4
21.24
3.40
10.0
50.0
19.53
3.31
12.0
53.6
17.98
3.21
14.0
57.2
16.57
3.12
16.0
60.8
15.28
3.02
18.0
64.4
14.10
2.93
20.0
68.0
13.03
2.83
22.0
71.6
12.05
2.73
24.0
75.2
11.16
2.64
26.0
78.8
10.34
2.54
28.0
82.4
9.59
2.45
30.0
86.0
8.90
2.35
32.0
89.6
8.26
2.26
34.0
93.2
7.68
2.17
36.0
96.8
7.15
2.08
Temperature
Resistence (k )
Voltage (V)*
7-2 RESISTENCE, VOLTAGE & SPECIFIC TEMPERATURE FOR SENSORS
Sensors “RT” (Ambien Temperature)
33
REMARKS:
1.
The sensor resistance has a variation of + 5%
2.
Sensor resistance measurement must be done after 3 minutes since the sensor has been exposed to that temperature,
this is necessary for getting a reliable value.
3.
For checking voltage, make sure of connection for PCB connector.
Содержание LTNS16121V /00
Страница 14: ...4 CIRCUIT DIAGRAM 14 ...