- Freezer Fan Error
1
46
Reset the unit and start Test Mode 1 (press
once the button on PCB).
Check the Fan motor voltage. Is fan motor
voltage 8V~13V?
TEST MODE 1
Voltage [V]
CON5
4
th
pin ~ 5
th
pin
8V~13V
TEST MODE 1
Voltage [V]
CON5
5
th
pin ~ 6
th
pin
Not 0V, 5V
CON5
Open the freezer
door and check the
air flow. Does it feel
windy?
Result SVC Support
Yes Go to step 3
No Go to step 2
Check the fan motor. Rotate fan using hand.
Does it feel sticky?
Result SVC Support
Yes Change the motor
2
No Go to step 3
3
Result SVC Support
Yes Go to step 4
No Replace PCB
Check the Fan motor voltage. Is fan feedback
voltage 0V, 5V?
4
Result SVC Support
Yes Change the motor
No Explain to customer
No
Checking
Result and SVC countermeasure
CON5