0.5 seconds
Conect
Compressor
is working
Operation
Conditions
Operation
Sequence
When the refrigerator is turn on
0.5 seconds
Freezer
fan is on
0.5 minutes
All loads
are off
Compressor
is on
0.5 seconds
Freezer fan
is on
If the temperature of the
defrosting sensor is
45 °C or above (for the
initial use after the
purchase or grounding).
If the temperature of
the defrosting sensor
is below 45 °C (after a
power failure or SVC).
When is returned from
TEST MODE.
29
7-1-6 OPERATION SEQUENCE FOR ELECTRIC COMPONENTS
The electric components operation such as compressor, defrost resistance and fans is sequently started in order to avoid noises
and damages in the parts, this can result when several components are running at the same time or after a test has finished.
5s
0.5s
Turn on
refrigerator
Defrost
heater is on
5.5s
Compensation
resistance is on
Compressor
and Freezer
fan are on
4min
0.5s
Defrost
heater is off
Compensation
resistance is off