- Defrost Sensor Error
4
5
40
Check the voltage between orange wires
(these are connected to PCB) for CON8.
No
Checking
Result and SVC countermeasure
0
Short
OFF
Open
Other value
Normal
1.
Check temperature and resistance
(see chart of section 7-2).
2.
Go to step 5.
Result SVC
Support
Replace the product.
Check the voltage between orange wires
(sensor wires) for CON8.
0V
Out of
Control
Replace (PCB)
5V
Other value
between
0V & 5V
Normal
Result SVC
Support
1.
Check temperature and resistance
(see chart of section 7-2).
2.
Explain to customer about loose
and dirty connectors.