1. Abnormal flow in Freezer Fan / Compressor
- 42 -
8-2-3
Troubleshooting (Without Display Error)
No Checking Flow
Result & SVC Action
1
2
3
Shutdown the refrigerator.
1. Turn on the refrigerator.
2. Remove the cover PCB, then input the TEST
MODE 1 by a short circuit between "TEST1" and
"TEST2" on PCB main
3. Check the fan rotation.
Remove the grille fan assembly, and check the
movement of freezer fan motor manually, feel
the rotation condition, then proceed.
SVC Action
Forced
Movement
Abnormal
Replace Freezer Fan
Motor / Compressor, then
turn on and check the
result.
Problem persists?
YES: Go to step 3
NO: Explain to
customer.
Free
Movement
Normal
Go to 3
Result
SVC Action
Air flow
Normal
Go to 5
No Air
flow
Abnormal
Go to 4
Result