5. Defrost Operation Failure
No Checking Flow
Result & SVC Action
1
2
3
Check the door seal to any abnormality
Reset the refrigerator, then input the TEST MODE 2.
(Make two shorts between “TEST1” and “TEST2” on
PCB main).
REMARK:
Defrost sensor must be cold in order to access this
mode (below 10°C).
The display confirms that it has entered the TEST
MODE 2, refer to appendix.
SVC Action
115V/127V/220V*
0V
Result
Go to 5
Change PCB.
Disconnect the refrigerator, remove the fan tray and
check the resistance of defrost assembly.
DEF
Sensor
DEF
Controller
Assy
DEF-HTR
Part
Result
SVC Action
See
appendix
"Heaters
table"
Go to 3
Other
Change
defrost
heater
0
?
OFF
Other
0
?
Go to 3
OFF
Change
defrost
controller.
Defrost
Controller
Assembly
Refer to
procedure of
defrost
sensor.
Defrost
Heater
Defrost
Sensor
4
Measure the voltage on CON1.
* According to nominal voltage of each country.
C
O
N
1
Def-HTR
Neutral
Содержание LTN16385PL