- 44 -
2. LED Refrigerator is not working.
No Checking Flow
Result & SVC Action
1
2
3
Unplug the refrigerator.
Remove the cover LED, and check if wire is
connected properly.
Check if there is a loose connection on the door
switch refrigerator.
Check if door switch refrigerator is activated by
movement.
SVC Action
Not
Correct
Abnormal
Reconnect LED
harness.
Problem persists?
YES: Go to step 2
NO: Explain to
customer.
Correct Normal
Go to 2
Result
SVC Action
Forced
Movement
Abnormal
Replace Door Switch.
Free
Movement
Normal
Go to 3
Result
Result
SVC Action
Connected
Go to 4
Loose
Connect firmly, and
try again.
Problem persists?
Yes: Go to step 4.
No: Explain to customer.
Содержание LTN16385PL
Страница 28: ... 28 ...
Страница 32: ...1 Main PCB CON3 CON2 CON4 CON1 2 LED Assembly 32 8 2 1 Components ...