- 48 -
4. Overcooling in refrigerator section.
No Checking Flow
Result & SVC Action
1
Check the
sensor in
“BLACK and WHITE”
on CON4.
resistance value of refrigerator
Refer to “Temperature table” for refrigerator sensor.
Result
SVC Action
OK
Go to 2
Abnormal
See section 2:
“Refrigerator Sensor Error”
Result
SVC Action
Air flow
Go to 4
No Air flow
Change PCB main.
2
Input TEST MODE 1 (Short circuit once "TEST1"
and "TEST2" PCB main).
Go to 3
3
1. Open the refrigerator door.
2. Press the refrigerator door switch manually.
3. Check the air flow
Result
SVC Action
Air flow
Change PCB main.
No Air flow
Go to 5
4
1. Input the TEST MODE 2 (Short circuit once more
in TEST1 and TEST2 on PCB main).
2. Open the refrigerator door.
3. Press the door switch manually.
4. Check the air flow.
Result
SVC Action
Correct
Change PCB main.
Incorrect
5
Check if sensors are placed correctly on the control
box.
Move the sensor to correct
position on Control Box.
Problem persists?
NO: Explain to customer.
YES: Change PCB.