3. Defrost Sensor Failure
No Checking Flow
Result & SVC Action
1
2
3
Check if there is a loose connection on CON4.
Unplug the PCB connectors and test the resistance
between the wires
"Orange and Orange"
on CON4
as shown in the image.
Accessing to Freezer Compartment, remove the fan
and check the resistance points (Orange wires).
Result
SVC Action
Connected
Go to 2
Loose
Connect firmly, and
try again.
Problem persists?
Yes: Go to step 2.
No: Explain to customer.
SVC Action
0?
Short
OFF
Open
Other Normal Check temperature and
resistance (Resistance
Table, page 54).
Go to 4
Result
Go to 3
SVC Action
0?
Short
OFF
Open
Other Correct Check temperature and
resistance (Resistance
Table, page 54).
Go to 4
Result
Change harness sensor.
4
Check between “Orange and Orange” on CON4 as
shown in the image.
SVC Action
0?
Short
OFF
Open
Result
Replace the refrigerator.
Connect the PCB wires
and the control box, then
connect to refrigerator.