Installation Manual
33
Installation
Function Code
Thermistor setting
Select ceiling height value by pressing
button. (01:Low, 02:Standard,
03:High, 04Very high)
3
Press button to save.
4
5
If moving to ceiling height selection menu by
pressing button, it indicates as picture
below.
2
If pressing button long for 3
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
1
Pressing button will exit settings mode.
❈
After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈
When exiting without pressing set button,
the manipulated value is not reflected.
This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product)
•
Ceiling height setting is available only for some products.
•
Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit.
•
Refer to the product manual for more details.
Ceiling Height Level
Description
01
Low
Decrease the indoor airflow rate 1 step from standard level
02
Standard
Set the indoor airflow rate as standard level
03
High
Increase indoor airflow rate 1 step from standard level
04
Very high
Increase indoor airflow rate 2 steps from standard level
<Ceiling Height Selection Table>
Installer Setting -Ceiling Height Selection
Содержание LT-C182QLE1
Страница 38: ......