Ceiling Cassette Air Conditioner
Installation
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H07RN-F approved by HAR
or SAA).
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
CAUTION
20mm
GN/YL
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
Capacity
1 Phase
18k/24k
30k
36k
48k/60k
2.1mm
2
3.5mm
2
5.5mm
2
6.5mm
2
Capacity
18k/24k/30k/36k
48k/60k
1 Phase
0.75mm
2
1.0mm
2
Capacity
18k/24k/30k/36k
48k/60k
1 Phase
0.75mm
2
1.0mm
2
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer
or its service agent.
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
Heat Pump Model
(5 lines)
Cooling Model
(4 lines)
Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
Remote Controller Cable
Connecting
Cable
Terminal Block of Outdoor Unit
1(L) 2(N) 1(L) 2(N) 3
4
1(L)
2(N)
3
Terminal Block of Indoor Unit
POWER INPUT
1 Phase
18k/24k/30k
Heatpump Model
4
1 Phase
36k/48k/60k
Heatpump Model
1(L) 2(N)
1(L) 2(N) 3
4
1(L)
2(N)
3
4
Terminal Block of Indoor Unit
POWER INPUT
Terminal Block of Outdoor Unit
1(L) 2(N) 1(L) 2(N) 3
1(L)
2(N)
3
Terminal Block of Indoor Unit
POWER INPUT
1 Phase
18k/24k/30k
Cooling Model
1 Phase
36k/48k/60k
Cooling Model
1(L) 2(N)
1(L) 2(N) 3
1(L)
2(N)
3
Terminal Block of Indoor Unit
POWER INPUT