9-23
CHECKING FLOW CHART BY FAILURE
Symptom
Check Point
CF2(IH LR Top Sensor Error)
Open / Short
1. Check the Top Sensor Connect
2. Check The Top Sensor Resistance.
2. SHORT
Yes
No
Reconnect
or adjust the
connection
Replace
The PCB
No
Yes
No
No
1. OPEN
Is the R921
disconnected?
Is the resistance of
R921 normal?
Normal
- approximately 1 kΩ
Is the CN92 disconnected or
loose Connection?
1. Sensor
Is the CN92 normal?
Measure the resistance
Normal : infinite
Abnormal : shorted
Replace The PCB
Replace The PCB