9-14
CHECKING FLOW CHART BY FAILURE
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and encoder is placed
in the Off
2. Press the button in the following order
+/- (“+”and “-” hold for 3 seconds
simultaneously)
3. Press the OVEN LIGHT button again.
4. Select the “t3” by press the “+” button.
5. Press the START button.
Normal :
Thermistor value at room temp is from
70˚F to 90
˚
F
Yes
Replace the
Relay PCB
3
4
Plug in the unit
Replace the Main PCB.
No