9-27
CHECKING FLOW CHART BY FAILURE
Symptom
Check Point
CF6(IH Right IGBT Sensor
Error
Open / Short
1. Check the IGBT Resistance
2. Check the IGBT Sensor
2. SHORT
Yes
No
Replace
The PCB
Replace
The PCB
No
No
No
1. OPEN
Is the R921
disconnected?
Is the TH91 and TH92
disconnected?
1. Sensor
Is the R901 and R912
normal?
Measure the resistance
Normal :
14kΩ~50kΩ
Abnormal :
Over 50kΩ
(Open)
Under 1Ω
(Short)
s the TH91 and TH92
normal?
Measure the resistance.
Normal :
18kΩ~28kΩ
Abnormal :
Over 28kΩ
(Open)
Under 1Ω
(Short)
Replace The PCB