9-7
CHECKING FLOW CHART BY FAILURE
3
Yes
Yes
Go to No 6
4
No
Range Of resistance
Plug in the unit
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN31 in main PCB
Normal- approximately 1.09kΩ at 25˚C
No
Replace the
defective
Thermistor
5
Yes
Unplug the unit
CN31
6
Replace the Relay PCB.
If the same phenomenon occurs even though
after replace Relay PCB, you should replace
the Main PCB
Heater
Resistance[
Ω
]
Approximately
Inner Broil
50
Outer Broil
23
Conv. Heater
23
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and encoder is
placed in the Off
2. Press the button in the following order
+/- (“+”and “-” hold for 3 seconds
simultaneously)
3. Press the OVEN LIGHT button again.
4. Select the “t3” by press the + button
5. Press the START button
Normal :
Thermistor value at room temp is from
70˚F to 90
˚
F
Содержание LSE4617ST
Страница 63: ...5 3 OVEN LIGHT Warming Drawer RR Cook top Element For Model LSE4617ST ...
Страница 64: ...5 4 Left Rear Center Rear Element RF Cook top Element Left Front Element For Model LSE4617ST ...
Страница 65: ...5 5 BROIL SPEED BROIL BAKE SPEED ROAST WARM PROOF EASY CLEAN ...
Страница 68: ...6 3 Composition of control SMPS PCB Encoder PCB CN02 CN01 CN41 P N EBR80595701 P N EBR80327001 ...
Страница 69: ...6 4 Composition of control Touch PCB Wifi PCB and Buzzer PCB P N EBR79627801 P N EAX66957201 P N EBR76332902 ...
Страница 105: ...9 30 CHECKING FLOW CHART BY FAILURE Symptom Check Point CFA Over Current 1 Replace The INVERTER PCB See page 3 13 ...
Страница 110: ...DOOR PARTS 1704 1382 1035 1015 W230 1703 1020 1008 102U W243 W222 W222 1000 102S 102L 173U W101 W101 1018 1009 W230 EV ...
Страница 113: ... EV 5134 5466 5466 5444 5612 5235 5235 5612 5444 COOKTOP PARTS II ...
Страница 116: ......