2) Connection of piping --Indoor
■
Preparing the indoor unit's piping and drain hose for
installation through the wall.
■
Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
■
Replace the plastic tubing holder in the original posi-
tion.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
■
Do not connect the cable to the indoor unit.
■
Make a small loop with the cable for easy connection
later.
3. Tape the tubing, drain hose and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper side
can cause drain pan to overflow inside the unit.
NOTE: If the drain hose is routed inside the room, insulate
the hose with an insulation material* so that dripping from
"sweating"(condensation) will not damage furniture or floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
■
Hook the indoor unit onto the upper portion of the instal-
lation plate.(Engage the two hooks of the rear top of the
indoor unit with the upper edge of the installation plate.)
Ensure that the hooks are properly seated on the instal-
lation plate by moving it left and right.
Press the lower left and right sides of the unit against the
installation plate until the hooks engage into their
slots(clicking sound).
5. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
■
Align the center of the pipings and sufficiently tighten
the flare nut by hand.
- 27 -
To remove the holder,
press the bottom of
chassis near the holder
upward and pull the tab
out of its hole.
Tubing holder
Pull
Press
2
1
Connecting
cable
Loop
Gas side
piping
Liquid side
piping
Drain hose
Drain hose
Connecting
cable
Indoor unit tubing
Flare nut
Pipings
Drain hose
When install, make sure that the
remaining parts must be removed
clearly so as not to damage the pip-
ing and drain hose, especially con-
necting cable.
CAUTION
For left rear piping