• Cooling, Soft Dry, Fan, Heating
• Sleep Mode
• Timer Mode
• Hot-start, Defrost
• Compressor ON
• BUZZER SOUND
• Power Input or Reset
: One short beep.
• When Operation Stop Button is pressed
: One long beep.
• When Remote Controller Buttons except for Operation Stop are pressed : Two short beep.
- 22 -
Display Function
Self-diagnosis Function
Operation Indicator
Sleep timer Indicator
Timer Indicator
Defrost Indicator or
Hot start Indicator
OUT
DOOR
: Cooling & Heating Model only
: only Cooling Model
CODE NO.
DIAGNOSIS
Operation Indicator LED Blinks
Unit Operation
①
Once
Still Operation
②
Outdoor pipe thermistor Short/Open
Twice
Outdoor Unit Off
③
5 times
Stop
Indoor room temperature thermistor or
pipe temperature thermistor Short/Open
Communication failure between indoor and
outdoor
• LED blinks as many times as code No. (0.5 second ON/0.5 second OFF) with 3 seconds interval.
• While the unit is off, no indication displays.