3. Insert the connecting cables, the drain pipe and
connecting pipings through the piping hole on
the wall.
4. Connect connecting pipings and indoor tubing,
and the drain hose and the drain pipe and place
the drain pipe into the chassis.
• Don’t connect the cable to the indoor unit.
• Make a small loop for easy conection later.
• Glue up the connection portion of drain hose and
drain pipe.
5. Bend the drain hose as shown in the figure and
bind the drain hose, the pipings and the con-
necting cables altogeter.
—17—
For left rear pipings
Torque wrench
Spanner
Indoor unit tubing
Flare nut Pipings
Drain hose
Adhesive
Drain pipe
Connecting cable
Connecting piping
Drain pipe
Indoor
Outdoor
;
;
Pipe Size
Torque
Liquid Side (1/4")
1.8kg·m
Gas Side (3/8")
4.2kg·m
Loop