—10—
5. Forced operation
• If you lose wireless remote controller, you can operate the unit with forced operation switch.
• The standand conditions are as following.
Cooling Model
Operation Mode
Cooling
Indoor FAN Speed
High
Setting temp.
22°C
4. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compres-
sor OFF temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
INDOOR FAN
LOW
Selecting
fan speed
ON
ON
ON
OFF
OFF
Operation
Cooling
Dry Operation
COMPRESSOR
SETTING TEMP.+1
°
C
(COMP. ON)
SETTING TEMP.-0.5
°
C
(COMP. OFF)
10 minutes
2 minutes
58 seconds
2 minutes
58 seconds
maximum
10 minutes
maximum
4 minutes