—21—
2) Connect the cable to the indoor unit
1. Connect the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection.
• Ensure that the color of wires of outdoor unit and
the terminal No. are the same to the indoor’s
respectively.
1) Cooling only type
2. Attach the Grille onto the cabinet.
• Grasp lower the left and the right side of the grille
and engage two tabs on the top inside edge of
the grille with two slots on the cabinet’s top front
edge.
• Press the grille toward to the cabinet until it will be
back into place.
❃
The power cord connected to the indoor unit should
be complied with 1.0mm
2
conductors.
(Type H05VV-F, TÜV or VDE Approval)
❃
The connecting cable connected to the indoor and
outdoor unit should be complied with 1.0mm
2
conductors.
(Type H07RN-F, TÜV or VDE Approval)
Connecting cable
BROWN
1(L) 2(N)
BLUE
GREEN/YELLOW
Terminals on the outdoor unit
Terminals on the indoor unit
Color of Wires
1(L) 2(N)