6. Wrap the insulation material around the con-
necting portion.
7. Wrap the tubing, the drain hose and the con-
necting cable with tape.
8. Indoor unit installation.
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge of
the installation plate,)
Insure the hooks are properly seated on the
installation plate by moving it in left and right.
—18—
Plastic Bands
• Wrap the insulation material around the
connecting portion.
Insulation material
Taping
Indoor/Outdoor
connecting cable
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
Drain hose
Connecting
cable
Press the lower left and right side of the unit against
the Installation Plate until the hooks engages with
their slots (sound click).
CAUTION :Take care to arrange the pipings,
drain hose and cables as the fea-
ture for inser ting it into the
indoor unit and mount the indor
unit on the installation plate.