—12—
1) Selection of the best location
1. Indoor unit.
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A Place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles.
2. Outdoor unit.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
• There should not be any animals or plants which
could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles.
More than 5cm
More than 5cm
More than 2.3m
More than 5cm
More than 10cm
More than 10cm
More than 60cm
More than 70cm
1. Installation of indoor, Outdoor unit
Install the indoor unit on the wall where the height
from the floor is more than 2.3 meters.
CAUTION
More than 10cm
More than 10cm
More than 70cm