AC Module System Installation Manual
Rev. 1.0
•
When you cut the extension cable, please be careful about the L1, L2, Neutral wire’s coating from
getting cut together. Damages on the cable can be a cause of electrical short leading to a fire.
•
To prevent the danger of the electric shock, make sure to turn off the circuit breaker.
•
Attach the AC Cable to the PV racks using the cable ties. Let the AC cables float way from the ground
surface or the roof.
•
All of AC cable connectors must be installed underneath the module, out of rain and sun. Do not leave
AC cable connectors in an environment of long-term exposure to direct sunlight or rain.
•
AC cables from the junction box to the distribution panel should be protected by a conduit.
38
※ Use a proper transition cable
for the first AC module connector.
Copyright © 2017 LG Electronics.
All Rights Reserved.
L1 (Black)
L2 (Red)
Neutral (White)
Cut here
Adjust an extension cable for junction box configuration
No damage
Cut
※ Use appropriate tools for stripping the outer insulation of the extension cable and the inner
three wire’s insulation.
Extension cable
Transition cable
Cut here
L1 (Black)
L2 (Red)
Neutral (White)
Extension cable
Transition cable
※ Use a proper transition cable
for the first AC module connector.