Spot Monitor
l
Dwell Time:
You can set the channel sequence
time to 2 SEC, 5 SEC, 10 SEC, 20 SEC, 30 SEC,
40 SEC, 50 SEC, 60 SEC, 70 SEC, 80 SEC or 90
SEC.
l
Event Popup:
Displays an event popup on the
spot monitor if motion, sensor or all (motion or sen-
sor) occur.
Event Settings
Sensor
l
In:
Displays the number of the SENSOR-IN termi-
nal.
l
Sensor Type:
The sensor state can be set to
either N.O. (Normally Open) or N.C. (Normally
Closed).
l
Camera:
Select the connected camera channel to
the SENSOR-IN terminal.
l
Alarm Out:
Select the alarm (relay) output number
for the ALARM-OUT terminal for the output alarm
(relay) signal.
Motion
l
Channel:
Select the channel to set motion detec-
tion.
l
Sensitivity:
Set the level of sensitivity for the cre-
ated motion detection area. Sensitivity can be set
from level 01 to 10 or OFF.
l
Alarm Out:
Select the number of the ALARM-OUT
terminal for the output alarm (relay) signal when
motion is detected.
l
Area:
Select the desired motion detection area on
the preview window screen.
-
b / B / v / V
: Moves the yellow cell box to
another cell zone.
- ENTER: Selects or cancels the motion
detection area at the current cell position.
- Press ESC to exit the settings.
Notes:
• You can select the motion detection area by using
the mouse.
- To select the area: Drag & drop a cell to the
right to select the motion detection area.
- To cancel area: Drag & drop a cell point of
a selected cell area to the left to cancel the
motion detection area.
• In the condition that illumination is low and the
outline of object is not clear enough to see,
regardless of sensitivity, Motion Event could be
possible not to happen. You must check Motion
Event before setting.