8-23
TROUBLESHOOTING
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
(1) press the CLEAR button
(2) press the upper BAKE and BROIL buttons
at the same time
(3) press the upper BAKE and BROIL buttons
at the same time again.
(4) press the NUM 3 button
Normal: Thermistor value at room temp is
from 70˚F to 90˚F
No
Replace the
Main PCB
4
Plug in the unit
Is the DLB relay normal?
Measure the resistance
Normal: infinite
Abnormal : shorted
No
Replace the
Main PCB
3
DLB
Relay
Tab 62(or Tab61)
and Tab 60 : RY60
yes
Current Oven Temp
Содержание LDG4313BD
Страница 50: ...6 1 Composition of control 1 Wiring Diagram Main system PCB ...
Страница 53: ...6 4 Composition of control NFC PCB P N EBR78789101 Buzzer PCB EBR76332902 ...
Страница 93: ......