4-3
Oven lamp
Components
Test procedures
Results
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
25.7 Ω ± 10%
If not replace
Igniter Type-1
Igniter Type-2
Oven (safety) valve
Ignition switch
1. Remove wire leads
2. Measure resistance.
1. Remove wire leads
2. Measure resistance.
Normal: 45 Ω ~ 400 Ω
(Room Temperature
Resistance)
Replace if:
Infinite(opened)
Normal: 50 Ω ~ 800 Ω
(Room Temperature
Resistance)
Replace if:
Infinite(opened)
1. Refer to page 3-28 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: Approximately
1 ~ 3 Ω
If not replace
1. Refer to pages 3-6, 3-7 for servicing procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
approximately
40° ~ 80°
other
Continuity
Upside Downside
Infinite
Содержание LDG4313BD
Страница 50: ...6 1 Composition of control 1 Wiring Diagram Main system PCB ...
Страница 53: ...6 4 Composition of control NFC PCB P N EBR78789101 Buzzer PCB EBR76332902 ...
Страница 93: ......