4-2
Micro Switch
( normally open type)
Oven Sensor
Door switch
1. Refer to pages 3-16, 3-17 for the servicing
procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-18 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 kΩ ± 10%
If not replace
Components
Test procedures
Results
NO
COM
Door latch
open
Door latch
locked
Continuity
Infinite
NOTE: After checking for the continuity of switch, make sure that they are
connected correctly
NO
COM
NOTE: Oven sensor is so sensitive to temperature
Do test after cooling down sufficiently
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
1. Refer to pages 3-8, 3-10 for the servicing
procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open Door closed
Continuity
Infinite
Door locking Motor
1. Refer to pages 3-16, 3-17 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
NO
COM
Normal: Approximately
2.6 kΩ ± 10%
If not replace
Abnormal: Infinite(open)
below 5Ω (shorted)