8-15
TROUBLESHOOTING
ICheck the operation of
door lock motor.
Press Lower Clear/Off
button for 3 seconds.
and try to open the door.
Does the door open?
Door lock icon turns on.
Note :
Just after self-clean start,
the door lock motor starts to rotate.
During this time if the door lock switch
does NOT operate properly after
rotating twice,
then supervising circuit detects
a Door Lock failure and
the F10 or F20 error code appears.
Yes
Go to No 2
It is normal. Check the
wiring
Door Lock System Failure,F10 or F20 ?
1
No
Plug in the unit
Is the Connector disconnected
or loose?
Check the following :
(1) Electric wiring of
relay in Main PCB
(2) Electric wiring of Locking
Motor and Micro Switch
(3) Electric wiring of CN60 and
CN61 of Main PCB
No
Reconnect.
If defective
harness,
replace or fix
2
Yes
Unplug the unit
CN61