-19-
■
Remote Control Operation Mode
• When the remote control is selected by the slide switch on the main unit, the appliance operates according to
the input by the remote control.
■
Protection of the evaporator pipe from frosting
• If the indoor pipe temp is below 0°C in 7 min. after the compressor operates without any pause while in cool-
ing cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor
evaporator pipe from frosting.
• When the indoor pipe temp is 7°C or higher after 3 min. pause of the compressor, the compressor and the
outdoor fan is turned on according to the condition of the room temperature.
■
Buzzer Sounding Operation
• When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.
• When the appliance-pause key is input by the remote control, the long "beep—" sounds.
• When a key is input by the remote control while the slide switch on the main unit of the appliance is on the
forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the
remote control signal cannot be received.
Содержание L2-C243AL1
Страница 52: ... 52 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Страница 53: ... 53 2 Outdoor MAIN P C B ASM ...
Страница 54: ... 54 3 Display Ass y ...
Страница 55: ... 55 Schematic Diagram 1 Indoor ...
Страница 56: ... 56 2 Outdoor ...
Страница 67: ...P No 3828A20097A July 2005 Printed in Korea ...