- 30 -
Connect the cable to the indoor unit
1. Connect the wires to the terminals on the control
board individually according to the outdoor unit con-
nection.
• Ensure that the color of the wires of outdoor unit and the
terminal No. are the same as those of indoor unit respec-
tively.
(Refer to Wiring diagram on page11.)
2. Attach the Grille onto the cabinet.
• Grasp lower the left and right side of the Grille and
engage four tabs on the top inside edge of the chassis.
• Press the Grille toward the chassis until it will be back into
place.
CAUTION
CAUTION
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Connecting cable
Main power source
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
Model
18K
1ø,230/208V
15A
24K
1ø,230/208V
20A
Power source Fuse or breaker
Capacity
• Be sure to refer to the wiring diagram label inside the
cover control and carry out the correct field wiring.
Wrong wiring can cause the unit to misoperate to result
in a fire hazard.
• Check local electrical codes and any specified wiring
instructions or limitations.
WARNING
Содержание L2-C243AL1
Страница 52: ... 52 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Страница 53: ... 53 2 Outdoor MAIN P C B ASM ...
Страница 54: ... 54 3 Display Ass y ...
Страница 55: ... 55 Schematic Diagram 1 Indoor ...
Страница 56: ... 56 2 Outdoor ...
Страница 67: ...P No 3828A20097A July 2005 Printed in Korea ...