- 44 -
Comp basic step.
Free joint outdoor unit has two compressor (TPS: Twin power system)
If overload Max. capacity, display error code in indoor unit.
Max. capacity
Step
Step 1
Step 2
Step 3
Outdoor
Operation Mode
COMP 40%(B)only
COMP 60%(A)only
COMP 100%(A+B) together
18k(Max. 19k)
Cooling
Qs<=7k
Qs<=12k
12k<Qs
Heating
-
Qs<=9k
12k<Qs
21k(Max. 23k)
Cooling
Qs<=9k
Qs<=12k
12k<Qs
Heating
-
Qs<=9k
12k<Qs
30k(Max. 33k)
Cooling
Qs<=12k
Qs<=19k
19k<Qs
Heating
Qs<=12k
Qs<=19k
19k<Qs
Outdoor
Max capacity
14k
14k combination
18k
19kcombination
21k
23k combination
30k
33k combination