- 14 -
6-2 PTC AND OLP
6
5
3
4
YES
NO
Normal operation of
Compressor is
impossible or poor.
Separate the PTC from
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
Tester or Wheat stone
bridge. (Figure 22)
Separate the OLP
from Compressor and
check resistance
value between two
terminals of OLP with
a Tester. (Figure 23)
Observation value at
220V/50Hz : 47
‰
– 30%
220 - 240V/50Hz : 47
‰
– 30%
110 -115V/60Hz : 6.8
‰
– 30%
220V/60Hz : 47
‰
– 30%
127V/60Hz : 22
‰
– 30%
The resistance value is
0 or several
hundreds
‰
or infinity.
Check another
electric components.
Replace OLP.
Check another
electric components.
Replace
PTC.
Figure 23
Figure 22