6-3 ANOTHER ELECTRIC COMPONENTS
t
Cooling is impossible
Compressor
doesn’t run.
Running state of
Compressor is poor.
Check a starting
voltage.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Low voltage.
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of motor
Compressor.
Replace
the compressor.
Replace
each component.
Raise the voltage.
Replace
each component.
Cause.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
t
Cooling ability is poor
Fan motor
doesn’t run.
Much frost are sticked
to the EVAPORATOR.
Poor contacting.
Coil is shorted.
Shorted.
Replace
each component.
Replace
each component.
Replace
each component.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
¥ Def. Sensor
¥ FUSE-M
Check current flowing
of the following
components.
¥ Heater plate
¥ Heater cord
Содержание B712Y*B
Страница 36: ...7 5 2 REPLACEMENT PARTS LIST 36 ...
Страница 37: ... 37 ...
Страница 38: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 38 ...
Страница 39: ... 39 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Страница 40: ... 40 7 5 5 V LED DISPLAY PART LIST ...
Страница 41: ...7 6 PWB DIAGRAM 41 ...
Страница 42: ... 42 ...
Страница 44: ... 44 149D 155J 149B 120 118 119 138 120 110 111 149B 405A 140A 133 405C 405C 404A ...
Страница 45: ... 45 101 122 241D 244C 244A 162 212C 212A 205A 241A 279A 123 102 241C 235A 205A 210A 173 172 241E ...
Страница 46: ...P No MFL38971701 MAR 2007 Printed in Korea ...