43 Product Data
YA Chassis
PTAC
6RWU0-06A
Function
Description
Display code
Over heating Protection
This feature prevents over heating of unit by electrical
heater located inside of the unit at the remote mode
(when the unit is connected with wall thermostat).
Freeze Protection
This feature prevents freezing of room at low tempera-
ture.
Remote Mode
When use the remote mode operation
Error
Code
Descriptions
Cause of Error
Check Point
72
Detect 4 Way Valve Transfer
Failure 7 Times
• Indoor / outdoor sensor short/open
• Disconnection of 4 way valve
connector
• 4 way valve open/short
• Burned part inside PCBA
• Check sensor status (Indoor / outdoor
middle pipe)
• Check connector for 4 way valve
• Check 4 way valve coil resistance
• Check CN-4 way output voltage