System Set-Up
Installation Manual
61
ENGLISH
Emergency operation
• Definition of terms
-
Trouble :
a problem which can stop system operation, and can be resumed temporally under
limited operation without certificated professional's assist.
-
Error :
problem which can stop system operation, and can be resumed ONLY after certificated
professional's check.
-
Emergency mode :
temporary heating operation while system met trouble.
• Objective of introducing 'trouble'
- Not like airconditioning unit, Air-to-Water heat pump is generally operating in whole winter
season without any system stopping.
- If system found some problem, which is not critical to system operating for yielding heating
energy, the system can temporarily continue in emergency mode operation with end user's
decision.
• Classified trouble
- Trouble is classified two levels according to the seriousness of the problem : Slight Trouble and
heavy trouble
-
Slight trouble :
Sensor trouble.
-
Heavy trouble :
Compressor cycle trouble.
-
Option trouble :
a problem is found for option operation such as water tank heating. In this
trouble, the troubled option is assumed as if it is not installed at the system.
• Emergency operation level
- When system met trouble, it stops operation and wait for userʼs decision : Calling service center
or starting emergency operation.
- To start emergency operation, user simply push ON / OFF button once more.
- Two different levels are prepared for emergency operation : High temperature cycle and low
temperature cycle.
- In emergency operation mode, user can not adjust target temperature.
※ It can not be operated, if the electric heater accessory is not installed.
High temperature cycle OFF 50°C 24°C 70°C
Low temperature cycle ON 30°C 19°C 50°C
DIP
Switch
Target
Leaving Water
Temperature
Target
Room Air
Temperature
Target
Sanitary Water
Temperature
Содержание AHBW Series
Страница 26: ...General Information 26 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW0 6A0 ...
Страница 27: ...General Information Installation Manual 27 ENGLISH Wiring Diagram Including Field Wiring AHBW1 6A0 ...
Страница 28: ...General Information 28 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW 8A0 ...
Страница 29: ...General Information Installation Manual 29 ENGLISH Wiring Diagram Including Field Wiring AHBW036H0 ...
Страница 81: ......