Installation of Unit
Installation Manual
35
ENGLISH
Strainer
- Strainer installed at the water inlet pipe of unit except AHBW036H0.
- The mesh of strainer should be clean and replacement periodically. (one or more / year)
Wired Remote Controller Installation
Op
eration u
nit
ZONE
1
2
3
4
Humid
ify
JET
AUTO
AUT
O SWING
OPERA
TION
FA
N SPEED
Progra
m s
et
SUB FUNCTION
SET
TEMP
Room T
em
p
HI
MED
LO
Heater
Defrost
Filter
Preheat
Out
door
Ti
m
e
Ti
mer
On
Set
no.
Time
Of
f
01
03
05
07
09
11
13
15
17
19
21
23
1.5 m
Direct
Sun ray contact area
no
no
no
yes
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature. Install the
remote controller about 1.5 m above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote
controller LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Fig.1 Typical locations for remote controller
Содержание AHBW Series
Страница 26: ...General Information 26 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW0 6A0 ...
Страница 27: ...General Information Installation Manual 27 ENGLISH Wiring Diagram Including Field Wiring AHBW1 6A0 ...
Страница 28: ...General Information 28 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW 8A0 ...
Страница 29: ...General Information Installation Manual 29 ENGLISH Wiring Diagram Including Field Wiring AHBW036H0 ...
Страница 81: ......