Wiring and Water Piping for Unit
38
Air-to-Water Heat Pump
Control terminal
(Terminal for connecting cable)
Main power terminal
(Terminal for power cable)
General consideration
Followings should be considered before beginning unit wiring.
• Field-supplied electrical components such as power switches, circuit breakers, wires, terminal
boxes, etc should be properly chosen with compliance with national electrical legislation or
regulation.
• Make it sure that supplied electricity is enough to operate the unit, electric heater, water tank
heater, etc. The capacity of fuse also selected according to the power consumption.
• The main electricity supply should be dedicated line. Sharing main electricity supply with other
devices such as washing machine or vacuum cleaner is not permitted.
• Before starting wiring job, the main electricity supply should be turned off until wiring is completed.
• When adjusting or changing wiring, the main electricity supply should be turned off and ground wire
should be connected securely.
• Installation place should be free from the attack of wild animal. For example, mice's wire attacking or
frog's entering into the unit may cause critical electrical accident.
• All power connections should be protected from dew condensation by thermal insulation.
• All electrical wiring should comply with national or local electrical legislation or regulation.
• The ground should be connected exactly. Do not earth the unit to the copper pipe, steel fence at the
veranda, city water outlet pipe, or any other conductivity materials.
• Fix all cable using cord clamp tightly. (When cable is not fixed with cord clamp, use additionally
supplied cable ties.)
Wiring procedure for power cable
Step 1.
: Disassemble the side panel from the unit by loosing screws.
Step 2.
: Connect power cable to main power terminal
See below figure for detailed information. When connecting earth cable, the
diameter of cable should be bigger than 1.6mm
2
to secure safety. The earth cable is
connected to the terminal block where earth symbol is marked.
Step 3.
: Use cable clamps (or cord clamps) to prevent unintended move of power cable.
Step 4.
: Reassemble the side panel to the unit by fastening screws.
Main power terminal
(Terminal for power cable)
Control terminal
(Terminal for connecting another
control box beside)
Cable clamp
Содержание AHBW Series
Страница 26: ...General Information 26 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW0 6A0 ...
Страница 27: ...General Information Installation Manual 27 ENGLISH Wiring Diagram Including Field Wiring AHBW1 6A0 ...
Страница 28: ...General Information 28 Air to Water Heat Pump Wiring Diagram Including Field Wiring AHBW 8A0 ...
Страница 29: ...General Information Installation Manual 29 ENGLISH Wiring Diagram Including Field Wiring AHBW036H0 ...
Страница 81: ......