- 61 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Self-Diagnosis Feature
21
DC Peak (IPM Fault)
O
Outdoor
22
CT 2 (Max CT)
O
Outdoor
23
DC Link Voltage is low
O
Outdoor
24
High Pressure / Low Pressure switch activated
O
Outdoor
25
Voltage is too low or too high
O
Outdoor
26
Problem in DC Compressor positioning
O
Outdoor
27
PSC Fault
O
Outdoor
28
DC Link Voltage is high
O
Outdoor
29
High current at Compressor phases
O
Outdoor
32
Temperature at discharge-pipe is too high
O
Outdoor
40
Problem in CT sensor
O
Outdoor
41
Problem in discharge-pipe temperature sensor
O
Outdoor
44
Problem in ambient temperature sensor
O
Outdoor
45
Problem in condenser-pipe temperature sensor
O
Outdoor
46
Problem in suction-pipe temperature sensor
O
Outdoor
52
Bad communication between internal PCBs
O
Outdoor
53
Bad communication between Indoor unit and Outdoor unit
O
Outdoor
60
EEPROM Checksum mismatched
O
Outdoor
61
Temperature at condenser-pipe is too high
O
Outdoor
62
Temperature at heatsink is too high
O
Outdoor
63
Temperature at condenser-pipe is too low
O
Outdoor
65
Problem in heatsink temperature sensor
O
Outdoor
73
Instant over current input
O
Outdoor
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
2 times
none
1 time
4 times
5 times
6 times
2 times
3 times
none
1 time
2 times
3 times
5 times
3 times
Code
No.
Description
Unit
Classification
LED Blinking
Slight
Trouble
Heavy
Trouble
Option
Trouble
Error
LED1 (Red)
LED2 Green)
2 times
3 times
4 times
5 times
6 times
6 times
Error Indicator (Outdoor PCB)
Outdoor Error
Ex) Error 21 (DC Peack)
1 Time
1 Time
1 Time
2 Times
2 Times
2 Times
1 Sec.
2 Sec.
2 Sec.
1 Sec.
1 Sec.
LED01G
(RED)
LED02G
(GREEN)
CAUTION
Precaution in Service or Check
Even after stopping the operation of product, it takes some time to discharge the remaining electricity of the electrolytic
capacitor that was charged early. Before conducting a checking or repairing job, pull out the plug out of the outlet and
make sure that the lamp on the control board outdoor unit is off.