Chapter 5 System Operation
890 USE 120 00
81
Powering Up and Powering Down the System, continued
Stop Function
If a fault occurs the output stage of the servo amplifier is switched off and the
Fault RA/RB contact is opened. In addition, a global error signal can be given out at
one of the digital outputs (terminals X3/16 and X3/17). These signals can be used
by the higher-level control to finish the current PLC cycle or to shut down the drive
(with additional brake or similar.).
For MHDA
pppp
A00 only: The built-in restart lock -AS- can be used to switch off the
drive via a positive action safety relay, so that personnel safety is ensured at the
drive shaft.
Instruments which are equipped with a selected "Brake" function use a special
sequence for switching off the output stage.
The Stop functions are defined in EN 60204 (VDE 0113), Para. 9.2.2, 9.2.5.3.
There are three categories of Stop functions:
l
Category 0: Shut down by immediately switching off the supply of energy to the
drive machinery (i.e an uncontrolled shut-down);
l
Category 1: A controlled shut-down, during which the supply of energy to the
drive machinery is maintained to perform the shut-down, and where the energy
supply is only interrupted when the shut-down has been completed;
l
Category 2: A controlled shut-down, where the supply of energy to the drive
machinery is maintained.
Every machine must be equipped with a Stop function to Category 0. Stop functions
to Categories I and/or 2 must be provided if the safety or functional requirements of
the machine make this necessary.
Содержание MHDA1004
Страница 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Страница 2: ......
Страница 4: ...Preface iv 890 USE 120 00...
Страница 14: ...Contents xiv 890 USE 120 00...
Страница 28: ...14...
Страница 46: ...32...
Страница 56: ...42...
Страница 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Страница 130: ...116 Continued on next page...
Страница 148: ...134...
Страница 172: ...158...
Страница 198: ...184...
Страница 204: ...Index 190 890 USE 120 00...