109
Environmental and Mechanical Specifications
Environmental
Specifications
Table
The following table provides 17D environmental specifications.
Continued on next page
ENVIRONMENTAL
Storage
High temperature,
non–operating
+70
°
C maximum
Low temperature,
non–operating
–25
°
C minimum
Humidity
Non–operating
95% RH maximum,
non-condensing
Operating
85% RH maximum,
non-condensing
Operating temperature
(ambient measured at fan inlet)
Full power
With linear derating
2.5% / °C
(available power: 75% of
rated output at 55
°
C)
0 ... 45
°
C
45 ... 55°C max
Vibration (operational)
10 ... 57 Hz
Sinusoidal, 0.75 mm
amplitude
57 ... 150 Hz
1.0 g
Air pressure
Operating:
Full power
With linear derating
1.5% / 100m
(available power: 75%
of rated output at
2500m)
1000 m (90 kPa)
1000 ... 2500m (73kPa) max
Transport
57 kPa (4540 m)
Contaminants
Pollution degree 2, as defined in EN60204/EN50178
Cooling
Models:
MHDA1004•00
MHDA1008•00
MHDA1017•00
MHDA1028•00
MHDA1056•00
Integrated heatsink with
internal fan.
Содержание MHDA1004
Страница 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Страница 2: ......
Страница 4: ...Preface iv 890 USE 120 00...
Страница 14: ...Contents xiv 890 USE 120 00...
Страница 28: ...14...
Страница 46: ...32...
Страница 56: ...42...
Страница 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Страница 130: ...116 Continued on next page...
Страница 148: ...134...
Страница 172: ...158...
Страница 198: ...184...
Страница 204: ...Index 190 890 USE 120 00...