115
Electrical Specifications - Power, continued
Motor Output
Specifications
Table
The following table provides 17D motor output specifications.
Note: Motors must be compatible with following table:
Parameter
Type
Model Number
Current
Output current (RMS)
Continuous
(Irms)
MHDA1004
•
00*
1.5 A
MHDA1008
•
00
3 A
MHDA1017
•
00
6 A
MHDA1028
•
00
10 A
MHDA1056
•
00
20 A
Intermittent
(Ipeak)**
MHDA1004
•
00
3 A
MHDA1008
•
00
6 A
MHDA1017
•
00
12 A
MHDA1028
•
00
20 A
MHDA1056
•
00
40 A
Switching frequency
8 kHz ± 0.1%
Cable length***
75 m (maximum)
Maximum cable capacitance (motor
phase to ground or shield)
150 pF/m
* For single phase main connection, the output current is limited to the output
current specifed above or 4 amps, whichever is lower.
** Duration depends on settings in Unilink.
*** Cable lengths exceeding 25 m require the use of motor choke AM0FIL001V056
T
I
2
T =
I
2
rms x 15s
I
2
peak - I
2
rms
Model
Inductance Min. (mH)
Inductance Max. (mH)
480V - 8 kHz
230V - 8 kHz
230V - 16 kHz
MHDA1004
•
00
16
8
4
100
MHDA1008
•
00
8
4
2
100
MHDA1017
•
00
4
2
1
100
MHDA1028
•
00
3.5
1.8
0.9
60
MHDA1056
•
00
1.5
0.8
0.4
30
Содержание MHDA1004
Страница 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Страница 2: ......
Страница 4: ...Preface iv 890 USE 120 00...
Страница 14: ...Contents xiv 890 USE 120 00...
Страница 28: ...14...
Страница 46: ...32...
Страница 56: ...42...
Страница 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Страница 130: ...116 Continued on next page...
Страница 148: ...134...
Страница 172: ...158...
Страница 198: ...184...
Страница 204: ...Index 190 890 USE 120 00...