I/O Expansion Cards, continued
Light-Emitting
Diodes (LEDs)
As shown in the diagram above, the two LEDs are mounted next to the terminals on
the expansion card. The green LED signals that the 24 Vdc bias supply is available
for the expansion card. The red LED signals faults in the outputs from the
expansion card (overload of the switching elements, short-circuit).
Terminal
Assignments
The terminal assignments for I/O connector X11A are provided in the following
table.
Continued on next page
CONNECTOR X11A
Terminal
Function
Signal
Identification
Notes
1
Input
A0
Motion task number 2
0
(LSB)
2
Input
A1
Motion task number 2
1
3
Input
A2
Motion task number 2
2
4
Input
A3
Motion task number 2
3
5
Input
A4
Motion task number 2
4
6
Input
A5
Motion task number 2
5
7
Input
A6
Motion task number 2
6
8
Input
A7
Motion task number 2
7
(MSB)
9
Input
Reference
See
UniLink
online help.
10
Input
Sfault clear
11
Input
Start MT Next
12
Input
Start Jog v=x
Содержание MHDA1004
Страница 1: ...Version 2 0 June 2003 31001643_K01_000_04 Lexium Servo Drive 17D Series User Guide...
Страница 2: ......
Страница 4: ...Preface iv 890 USE 120 00...
Страница 14: ...Contents xiv 890 USE 120 00...
Страница 28: ...14...
Страница 46: ...32...
Страница 56: ...42...
Страница 112: ...Chapter 5 System Operation 98 890 USE 120 00...
Страница 130: ...116 Continued on next page...
Страница 148: ...134...
Страница 172: ...158...
Страница 198: ...184...
Страница 204: ...Index 190 890 USE 120 00...