Commissioning and configuration
66
MA 255
i
Le
u
ze electronic
12.5
EDS file - detailed description
12.5.1
Class 1 Identity object
Object class 1 = 01
H
Services:
• Get Attribute Single
• Reset type 0x05
In the network configuration (e.g., RSNetWorx), it is possible to specify when entering the
individual participants in the scan list which attributes of the scanner are to be monitored
from the identity object.
The selection is made in the "Electronic key" field. Attributes marked there are monitored.
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
1
1
1
Vendor-Id
16
UINT
524
-
-
Get
2
Device type
16
UINT
12
-
Get
3
Product code
16
UINT
1004
-
Get
4
Revision
(Major, minor)
16
Struct{
USINT major,
USINT minor};
Major = 1,
Minor = 1
Major = 1,
Minor = 1
Major = 127,
Minor = 999
Get
5
Status
16
WORD
See CIP specification (5-2.2.1.5 status)
Get
6
Serial number
32
UDINT
Manufacturer specific
Get
7
Product name
(max. 32)
x 8
SHORT_STRING
"MA 255i"
Get