Commissioning and configuration
Le
u
ze electronic
MA 255
i
61
TNT
35/7-2
4
V
12.2
Starting the device
Apply the supply v18 … 30 V DC (+24 V DC model); the MA 255
i
starts up.
12.3
Configuration steps for a Rockwell control
The following steps are necessary for commissioning with a Rockwell control:
• Creating the hardware configuration in the DeviceNet planning tool/the control
(e.g. RSNetWorx)
• Installation of the EDS file
• Setting the parameters on the MA
12.3.1
Setting the hardware configuration
Enter the MA 255
i
in your project in the configuration of the DeviceNet system. Proceed as
follows:
First, load the EDS file for the device via EDS wizard into the PLC database.
After loading, select the device via the device list and enter it into the HW manager via
Drag&Drop.
Open the input dialog for setting the address and additional parameters by double-
clicking on the device symbol and make the desired entries here.
Finally, transmit the values to the device via download.