Fast commissioning / operating principle
12
MA 255
i
Le
u
ze electronic
3.3.1
Connecting the Leuze device
To connect the Leuze device to the internal RS 232 device interface, open the housing
of the MA 255
i
and guide the corresponding device cable (see chapter 14.7, e.g., KB 031
for BCL 32) through the middle threaded opening.
Connect the cable to the internal device interface (
X30
,
X31
or
X32
,
see chapter 7.5.1
Use rotary switch
S4
(see chapter 8.2.5) to select the connected device.
Now screw the PG cable gland into the threaded opening to provide strain relief and
ensure protection class IP 65.
3.3.2
Setting the DeviceNet device address
Set the station address of the gateway using the two rotary switches
S1
and
S2
(ones
and tens places).
Notice!
The DeviceNet permits an address range from 0 to 63. Other addresses must not be used
for data communication.
Figure 3.2:
Rotary switch for setting the address
Ones
Tens