Electrical connection
Le
u
ze electronic
MA 255
i
3
1
TNT
35/7-2
4
V
7.4
BUS OUT
Table 7.4:
Pin assignments for DeviceNet BUS OUT
For the host connection of the MA 255
i
, the ready-made KB DN/CAN-xxxxx-Sx cables
are preferred, table 14.5 "Bus connection cable for the MA 255i" on page 80.
Notice!
Ensure adequate shielding. For the devices and ready-made cables offered by Leuze
electronic, the shield is on PIN 1.
7.4.1
Termination of the DeviceNet
The last physical DeviceNet participant must be terminated with a terminating resistor (see
"Accessory terminating resistor" on page 77).
Attention!
After DeviceNet specification (Volume 3: DeviceNet Adaptation of CIP Chapter 8, Physical
Layer 8-3.3 Connectors), use of the BUS OUT connection is not allowed.
BUS OUT (5-pin socket, A-coded)
Pin
Name
Remark
1
Drain
Shield
2
V+
Supply voltage data V+
3
V-
Supply voltage data V-
4
CAN_H
Data signal CAN_H
5
CAN_L
Data signal CAN_L
Thread
FE
Functional earth (housing)
1
2
3
4
5
BUS OUT
V+
CAN_H
DRAIN
V-
CAN_L
M 12 socket
(A-coded)