Technical data and ordering data
Leuze electronic
MSI 100/200
114
Dimensions and weight
Screw connection
Spring-cage connection
Width / height / depth
22.5 mm / 99 mm / 114.5 mm
22.5 mm / 112 mm / 114.5 mm
Weight with plugs
Approx. 140 g
Approx. 140 g
Dimensions and connection data
Screw connection
Spring-cage connection
Conductor cross-section (rigid/flexible)
0.2 mm² … 2.5 mm²
AWG 24 … 12
0.2 mm² … 1.5 mm²
AWG 24 … 16
Stripped length
7 mm
8 mm
Screw thread
M3
-
Tightening torque
0.5 Nm … 0.6 Nm
5 lb in … 7 lb in
-
Environmental conditions
Ambient temperature
Operation
Storage/transport
- 20 °C … + 55 °C (see Derating)
- 20 °C … + 70 °C
Air humidity
Operation
Storage/transport
75% (average, 85% occasionally)
75% (average, 85% occasionally)
Air pressure
Operation
Storage/transport
70 kPa … 108 kPa (up to 3000 m above sea level)
66 kPa … 108 kPa (up to 3500 m above sea level)
Operation altitude
Max. 2000 m above sea level
See appendix "Use of MSI 100/200 modules at altitudes above 2000 m above
sea level" on page 125
Shock
10g
t = 11 ms (three shocks in each spatial direction)
10g
t = 16 ms (continuous shock; 1000 shocks in each spatial direction)
Vibration (operation)
2g
UL note:
To maintain UL approval, use copper cables that are designed for operating temperatures of > 75 °C.