Configuration and commissioning
Leuze electronic
MSI 100/200
77
10 Configuration and commissioning
Qualified personnel
The MSI 100/200 system may only be configured and commissioned by qualified personnel.
See "Qualified personnel" on page 10.
10.1
Example for configuration and commissioning
Figure 10-1
Flow chart: Example configuration and commissioning (1 of 3)
For detailed information, please refer to the sections cited and the help system of the
MSIsafesoft configuration software.
MSIsafesoft:
Configure inputs/outputs of the safety
module and the extension devices
Double-click on the device representation in the
hardware editor to open the safe configuration
editor for this device.
Develop safety logic in the connection editor
- Insert input/output signals from the hardware editor
- Enter signal information ("Project", "Assignment List" menu)
- Insert functions and function blocks from the toolbox
- Connect the objects
- Safety networks
MSIsafesoft:
Check project
Errors in the project?
>> Message window in
MSIsafesoft
Yes
No
Continued (
A
) ...
... Continued
(
from B
)
MSIsafesoft:
Define bus configuration
Use drag & drop to move extension modules from the tool-
box ("Hardware" compartment) to the hardware editor